Product Upgrades

Electro-Sensors Product Upgrades:

SG1000 (models excluding the RA):

All of our SG1000 units have been upgraded to include a user friendly calibration method.  Prior to July 2016 all SG1000 units required powering down the units and following the designated calibration procedure.  Models created after mid-October 2016 have a new calibration method that allows the user to calibrate their unit with the power still on.  
The following excerpt is taken from new SG1000 Installation Manuals.  

There are two ways to enter Calibration Mode:
• One, remove the +24Vdc power, press-in and hold the calibration switch SW2, then reapply the +24Vdc power. (This is referred to as “power-up” entry into calibration mode).
• Or two, while the SG1000 remains powered, press-in and hold the calibration switch SW2, for a constant 5 to 6 seconds. (This is referred to as “on-the-fly” entry into calibration mode).
(Do not press SW2 multiple times or allow it to change state, just keep it pressed-in). Continue to keep SW2 pressed-in for a few seconds until the SG1000 outputs a constant 12 mA from its signal line, then release the button.
(Please note that the calibration method of the SG1000RA is slightly different)

The SG1000B new “on-the-fly” calibration feature’s ECO was implemented on about 07-06-2016 (the old “power-up” calibration feature is still available in this software version).
The SG1000C new “on-the-fly” calibration feature’s ECO was implemented on about 08-17-2016 (the old “power-up” calibration feature is still available in this software version).
The SG1000A, SG1000D,  SG1000E,  SG1000F, new “on-the-fly” calibration feature’s ECO was implemented on about 10-20-2016 (the old “power-up” calibration feature is still available in this software version).

If you or your facility would like to upgrade your old SG1000 units to the new software please contact us at sales@electro-sensors.com for a quote.